Investigation Of Performance Characteristics For Sanitary Plumbing Fixtures
Download Investigation Of Performance Characteristics For Sanitary Plumbing Fixtures full books in PDF, epub, and Kindle. Read online free Investigation Of Performance Characteristics For Sanitary Plumbing Fixtures ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads.
Author |
: Institute for Applied Technology (U.S.). Building Research Division |
Publisher |
: |
Total Pages |
: 84 |
Release |
: 1970 |
ISBN-10 |
: UOM:39015031961553 |
ISBN-13 |
: |
Rating |
: 4/5 (53 Downloads) |
Synopsis Investigation of Performance Characteristics for Sanitary Plumbing Fixtures by : Institute for Applied Technology (U.S.). Building Research Division
Author |
: |
Publisher |
: National Academies |
Total Pages |
: 288 |
Release |
: 1968 |
ISBN-10 |
: NAP:15349 |
ISBN-13 |
: |
Rating |
: 4/5 (49 Downloads) |
Synopsis Performance Characteristics for Sanitary Plumbing Fixtures by :
Author |
: |
Publisher |
: |
Total Pages |
: 20 |
Release |
: 1970-07 |
ISBN-10 |
: MINN:30000010247520 |
ISBN-13 |
: |
Rating |
: 4/5 (20 Downloads) |
Synopsis Building Science Series by :
Author |
: United States. National Bureau of Standards |
Publisher |
: |
Total Pages |
: 184 |
Release |
: 1970 |
ISBN-10 |
: UOM:39015002112731 |
ISBN-13 |
: |
Rating |
: 4/5 (31 Downloads) |
Synopsis Building Science Series by : United States. National Bureau of Standards
Author |
: Bruce E. Foster (Of the United States National Bureau of Standards) |
Publisher |
: |
Total Pages |
: 824 |
Release |
: 1972 |
ISBN-10 |
: UOM:39015086432666 |
ISBN-13 |
: |
Rating |
: 4/5 (66 Downloads) |
Synopsis Performance Concept in Buildings by : Bruce E. Foster (Of the United States National Bureau of Standards)
Author |
: United States. National Bureau of Standards |
Publisher |
: |
Total Pages |
: 804 |
Release |
: 1978 |
ISBN-10 |
: UIUC:30112104127235 |
ISBN-13 |
: |
Rating |
: 4/5 (35 Downloads) |
Synopsis Catalog of National Bureau of Standards Publications, 1966-1976 by : United States. National Bureau of Standards
Author |
: United States. National Bureau of Standards. Technical Information and Publications Division |
Publisher |
: |
Total Pages |
: 804 |
Release |
: 1978 |
ISBN-10 |
: UOM:39015086578187 |
ISBN-13 |
: |
Rating |
: 4/5 (87 Downloads) |
Synopsis Catalog of National Bureau of Standards Publications, 1966-1976: pt. 1 Citations and abstracts. v. 2. pt. 1. Key word index (A through L). v. 2. pt. 2. Key word index (M through Z) by : United States. National Bureau of Standards. Technical Information and Publications Division
Author |
: James Bryson |
Publisher |
: |
Total Pages |
: 24 |
Release |
: 1970 |
ISBN-10 |
: UOM:39015031961645 |
ISBN-13 |
: |
Rating |
: 4/5 (45 Downloads) |
Synopsis Flexural Behavior of Prestressed Concrete Composite Tee-beams by : James Bryson
Prestressed Tee-beams constructed by the split-beam method were tested to failure in flexure to study the behavior and ultimate strength of these beams and to compare their flexural characteristics with those of prestressed beams of conventional construction. Results showed that composite split-beams behaved similarly to the monolithically constructed beams on the basis of flexural response and ultimate load.
Author |
: Richard D. Marshall |
Publisher |
: |
Total Pages |
: 180 |
Release |
: 1970 |
ISBN-10 |
: UIUC:30112105152232 |
ISBN-13 |
: |
Rating |
: 4/5 (32 Downloads) |
Synopsis Proceedings by : Richard D. Marshall
Author |
: Robert S. Wyly |
Publisher |
: |
Total Pages |
: 40 |
Release |
: 1972 |
ISBN-10 |
: UOM:39015031961736 |
ISBN-13 |
: |
Rating |
: 4/5 (36 Downloads) |
Synopsis Performance of a Single-stack DWV System Utilizing Low-angle Stack-branch Confluence and Bottom Shunt Venting by : Robert S. Wyly
One of the performance requirements of great importance in relation to plumbing is hydraulic adequacy or hydraulic performance, which is related primarily to the general attribute of health and safety.The scope of the presentation is limited to certain aspects of the hydraulic performance of sanitary drain-waste-vent (DWV) systems. Considerable savings in material and labor costs have been reported to be possible through the use of a single-stack drainage system in place of a conventional system.The development of the experimental work reported herein came about as the result of a request to make technical recommendations concerning the suitability of such a system in a particular installation.Described is a test program developed looking toward the evaluation of the system against the essential criteria.