Method And Apparatus For Ultrasonic Doppler Velocimetry Using Speed Of Sound And Reflection Mode Pulsed Wideband Doppler
Download Method And Apparatus For Ultrasonic Doppler Velocimetry Using Speed Of Sound And Reflection Mode Pulsed Wideband Doppler full books in PDF, epub, and Kindle. Read online free Method And Apparatus For Ultrasonic Doppler Velocimetry Using Speed Of Sound And Reflection Mode Pulsed Wideband Doppler ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads.
Author |
: |
Publisher |
: |
Total Pages |
: |
Release |
: 2000 |
ISBN-10 |
: OCLC:873774382 |
ISBN-13 |
: |
Rating |
: 4/5 (82 Downloads) |
Synopsis Method and Apparatus for Ultrasonic Doppler Velocimetry Using Speed of Sound and Reflection Mode Pulsed Wideband Doppler by :
According to the present invention, a method and apparatus rely upon tomographic measurement of the speed of sound and fluid velocity in a pipe. The invention provides a more accurate profile of velocity within flow fields where the speed of sound varies within the cross-section of the pipe. This profile is obtained by reconstruction of the velocity profile from the local speed of sound measurement simultaneously with the flow velocity. The method of the present invention is real-time tomographic ultrasonic Doppler velocimetry utilizing a to plurality of ultrasonic transmission and reflection measurements along two orthogonal sets of parallel acoustic lines-of-sight. The fluid velocity profile and the acoustic velocity profile are determined by iteration between determining a fluid velocity profile and measuring local acoustic velocity until convergence is reached.
Author |
: United States. Patent and Trademark Office |
Publisher |
: |
Total Pages |
: 1142 |
Release |
: 2000 |
ISBN-10 |
: WISC:89071942676 |
ISBN-13 |
: |
Rating |
: 4/5 (76 Downloads) |
Synopsis Official Gazette of the United States Patent and Trademark Office by : United States. Patent and Trademark Office
Author |
: |
Publisher |
: |
Total Pages |
: 1134 |
Release |
: 2000 |
ISBN-10 |
: PSU:000066182252 |
ISBN-13 |
: |
Rating |
: 4/5 (52 Downloads) |
Synopsis Official Gazette of the United States Patent and Trademark Office by :
Author |
: Frederick W. Kremkau |
Publisher |
: W.B. Saunders Company |
Total Pages |
: 320 |
Release |
: 1990 |
ISBN-10 |
: CHI:36217377 |
ISBN-13 |
: |
Rating |
: 4/5 (77 Downloads) |
Synopsis Doppler Ultrasound by : Frederick W. Kremkau
An introductory text that explains how Doppler ultrasound works in simple step-by-step language. The book discusses the fundamental physical principles and instrumentation of Doppler ultrasound. Features include exercises, a multiple choice practical examination and a glossary of terms.
Author |
: Matthias Messer |
Publisher |
: |
Total Pages |
: |
Release |
: 2005 |
ISBN-10 |
: OCLC:63160240 |
ISBN-13 |
: |
Rating |
: 4/5 (40 Downloads) |
Synopsis Pulsed Ultrasonic Doppler Velocimetry for Measurement of Velocity Profiles in Small Channels and Capplilaries by : Matthias Messer
Pulsed ultrasound Doppler velocimetry proved to be capable of measuring velocities accurately (relative error less than 0.5 percent). In this research, the limitations of the method are investigated when measuring: in channels with a small thickness compared to the transducer diameter, at low velocities and in the presence of a flow reversal area. A review of the fundamentals of pulsed ultrasound Doppler velocimetry reveals that the accuracy of the measured velocity field mainly depends on the shape of the acoustic beam through the flow field and the intensity of the echo from the incident particles where the velocity is being measured. The ultrasonic transducer turned out to be most critical component of the system. Fundamental limitations of the method are identified. With ultrasonic beam measurements, the beam shape and echo intensity is further investigated. In general, the shape of the ultrasonic beam varies depending on the frequency and diameter of the emitter as well as the characteristics of the acoustic interface that the beam encounters. Moreover, the most promising transducer to measure velocity profiles in small channels is identified. Since the application of pulsed ultrasound Doppler velocimetry often involves the propagation of the ultrasonic burst through Plexiglas, the effect of Plexiglas walls on the measured velocity profile is analyzed and quantified in detail. The transducers ringing effect and the saturation region caused by highly absorbing acoustic interfaces are identified as limitations of the method. By comparing measurement results in the small rectangular channel to numerically calculated results, further limitations of the method are identified. It was not possible to determine velocities correctly throughout the whole channel at low flow rates, in small geometries and in the flow separation region. A discrepancy between the maximum measured velocity, velocity profile perturbations and incorrect velocity determination at the far channel wall were main shortcomings. Measurement results are improved by changes in the Doppler angle, the flow rate and the particle concentration. Suggestions to enhance the measurement system, especially its spatial resolution, and to further investigate acoustic wave interactions are made.
Author |
: Jørgen Arendt Jensen |
Publisher |
: Cambridge University Press |
Total Pages |
: 344 |
Release |
: 1996-03-29 |
ISBN-10 |
: 0521464846 |
ISBN-13 |
: 9780521464840 |
Rating |
: 4/5 (46 Downloads) |
Synopsis Estimation of Blood Velocities Using Ultrasound by : Jørgen Arendt Jensen
A clear, extensively illustrated treatment of ultrasound systems used in estimating blood velocities.
Author |
: David H. Evans |
Publisher |
: |
Total Pages |
: 330 |
Release |
: 1989-03-27 |
ISBN-10 |
: UOM:39015017920870 |
ISBN-13 |
: |
Rating |
: 4/5 (70 Downloads) |
Synopsis Doppler Ultrasound by : David H. Evans
A description of the physical principles upon which Doppler ultrasound is based and the instrumentation and processing necessary to measure and record the flows from within the body. Clinical applications are surveyed to demonstrate the method's potential and illustrate technical data.
Author |
: Yasushi Takeda |
Publisher |
: Springer Science & Business Media |
Total Pages |
: 278 |
Release |
: 2012-08-31 |
ISBN-10 |
: 9784431540267 |
ISBN-13 |
: 4431540261 |
Rating |
: 4/5 (67 Downloads) |
Synopsis Ultrasonic Doppler Velocity Profiler for Fluid Flow by : Yasushi Takeda
The ultrasonic velocity profile (UVP) method, first developed in medical engineering, is now widely used in clinical settings. The fluid mechanical basis of UVP was established in investigations by the author and his colleagues with work demonstrating that UVP is a powerful new tool in experimental fluid mechanics. There are diverse examples, ranging from problems in fundamental fluid dynamics to applied problems in mechanical, chemical, nuclear, and environmental engineering. In all these problems, the methodological principle in fluid mechanics was converted from point measurements to spatio-temporal measurements along a line. This book is the first monograph on UVP that offers comprehensive information about the method, its principles, its practice, and applied examples, and which serves both current and new users. Current users can confirm that their application configurations are correct, which will help them to improve the configurations so as to make them more efficient and effective. New users will become familiar with the method, to design applications on a physically correct basis for performing measurements accurately. Additionally, the appendix provides necessary practical information, such as acoustic properties.
Author |
: N. Sad Chemloul |
Publisher |
: |
Total Pages |
: |
Release |
: 2012 |
ISBN-10 |
: OCLC:1154237472 |
ISBN-13 |
: |
Rating |
: 4/5 (72 Downloads) |
Synopsis Application of Pulsed Ultrasonic Doppler Velocimetry to the Simultaneous Measurement of Velocity and Concentration Profiles in Two Phase Flow by : N. Sad Chemloul
Application of Pulsed Ultrasonic Doppler Velocimetry to the Simultaneous Measurement of Velocity and Concentration Profiles in Two Phase Flow.
Author |
: David H. Evans |
Publisher |
: John Wiley & Sons |
Total Pages |
: 468 |
Release |
: 2000 |
ISBN-10 |
: UOM:39015048514825 |
ISBN-13 |
: |
Rating |
: 4/5 (25 Downloads) |
Synopsis Doppler Ultrasound by : David H. Evans
Doppler ultrasound is an imaging technique used in the diagnosis of diseases where the measurement of blood flow is a factor. This new edition provides a theoretical basis for users of the technique and provides an up-to-date survey of new innovations.